{"product_id":"kemper-khs-hygienespulung-pro-68903-1-anschluss-g-3-4","title":"Kemper KHS Hygiene Flushing PRO 68903, 1 connection, G 3\/4","description":"\u003cstrong\u003eKHS Hygiene Flushing PRO with flow sensor, with one connection, figure 689 03 007\u003c\/strong\u003e\u003ch3\u003eProduct features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eparticularly suitable for hygiene-critical buildings\u003c\/li\u003e\n\u003cli\u003efor automatically triggered water changes to ensure intended operation\u003c\/li\u003e\n\u003cli\u003eenables turbulent water changes in potable water pipes up to DN 50\u003c\/li\u003e\n\u003cli\u003ewith one connection (water change group) for cold potable water (PWC)\u003c\/li\u003e\n\u003cli\u003emetal parts in contact with the medium made of dezincification-resistant and corrosion-resistant red brass, resistant to aggressive water, stainless steel, and potable water-approved plastics\u003c\/li\u003e\n\u003cli\u003efor installation in all installation situations (surface-mounted and concealed)\u003c\/li\u003e\n\u003cli\u003efor installation in wet construction or in pre-wall systems\u003c\/li\u003e\n\u003cli\u003esmall installation dimensions\u003c\/li\u003e\n\u003cli\u003equick assembly by means of drilling template\u003c\/li\u003e\n\u003cli\u003einstallation frame (incl. depth compensation) and fastening material\u003c\/li\u003e\n\u003cli\u003eremovable cover (incl. cover security) with push-to-open magnetic latch function\u003c\/li\u003e\n\u003cli\u003egenerous inspection opening\u003c\/li\u003e\n\u003cli\u003eexternal thread for flat-sealing screw connections\u003c\/li\u003e\n\u003cli\u003ewith shut-off function for maintenance\u003c\/li\u003e\n\u003cli\u003esolenoid valve with integrated fine sieve\u003c\/li\u003e\n\u003cli\u003eflow and temperature measuring armature (Pt1000) for recording flushing volumes\u003c\/li\u003e\n\u003cli\u003eflow rate 10l\/min (5l\/min or 15l\/min with optional accessories)\u003c\/li\u003e\n\u003cli\u003efactory-assembled flushing set for commissioning\u003c\/li\u003e\n\u003cli\u003eall functional components can be serviced without tools\u003c\/li\u003e\n\u003cli\u003eintegrated overflow monitoring\u003c\/li\u003e\n\u003cli\u003eintegrated siphon (\u003e 45 l\/min) with removable odor trap cap\u003c\/li\u003e\n\u003cli\u003efree outlet according to DIN EN 1717\u003c\/li\u003e\n\u003cli\u003etrap seal depth 50mm according to DIN 1986-100\u003c\/li\u003e\n\u003cli\u003edrain nominal size (DN 40 and DN 50)\u003c\/li\u003e\n\u003cli\u003econtrol unit PRO\u003c\/li\u003e\n\u003cli\u003eoperation via WLAN (can be switched off) using modern access point technology\u003c\/li\u003e\n\u003cli\u003eseven timers for individual flushing strategy\u003c\/li\u003e\n\u003cli\u003einterval-, time-, and volume-controlled flushing measures\u003c\/li\u003e\n\u003cli\u003etemperature- and usage-controlled flushing measures (only possible with additional Pt1000 temperature measuring armature)\u003c\/li\u003e\n\u003cli\u003edigital commissioning and maintenance assistant\u003c\/li\u003e\n\u003cli\u003ereading of analyses and logs via WLAN and USB\u003c\/li\u003e\n\u003cli\u003evisualized flushing history\u003c\/li\u003e\n\u003cli\u003econnection to KHS Mini control system possible\u003c\/li\u003e\n\u003cli\u003enetworking of up to 60 hygiene flushings possible\u003c\/li\u003e\n\u003cli\u003eup to 100,000 event entries to prove intended operation\u003c\/li\u003e\n\u003cli\u003epotential-free fault reporting contact\u003c\/li\u003e\n\u003cli\u003eintegration into BMS (BACnet \u0026 Modbus) via KEMPER Hygiene system KHS\u003c\/li\u003e\n\u003cli\u003econnection to BMS via Digital I\/O\u003c\/li\u003e\n\u003cli\u003eautomatic detection and checking of all functional components\u003c\/li\u003e\n\u003cli\u003erecording of media temperature with optional accessories (KHS Pt1000 temperature measuring armature)\u003c\/li\u003e\n\u003cli\u003ebuzzer for fault messages (in three volume levels)\u003c\/li\u003e\n\u003cli\u003eLED status indicator\u003c\/li\u003e\n\u003cli\u003eexternal connections exclusively as fixed connection in the housing (no external junction boxes necessary)\u003c\/li\u003e\n\u003cli\u003econtroller pre-assembled in the housing (output cable length 5m)\u003c\/li\u003e\n\u003cli\u003ecan be expanded with a second water change group, e.g. for hot potable water (PWH)\u003c\/li\u003e\n\u003cli\u003emaintenance and commissioning of the system on request\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eStandards and approvals\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDVGW approval\u003c\/li\u003e\n\u003cli\u003eSVGW approval\u003c\/li\u003e\n\u003cli\u003eWRAS approval\u003c\/li\u003e\n\u003cli\u003eKIWA approval\u003c\/li\u003e\n\u003cli\u003eBELGAQUA approval\u003c\/li\u003e\n\u003cli\u003eaccording to UBA BWGL metals\u003c\/li\u003e\n\u003cli\u003esound insulation approval according to DIN EN ISO 3822 Class 1 (up to 30 l\/min)\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical data\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003epressure rating PN 10\u003c\/li\u003e\n\u003cli\u003emax. operating temperature 70 °C\u003c\/li\u003e\n\u003cli\u003eprotection class IP44\u003c\/li\u003e\n\u003cli\u003epower supply 230 V AC\u003c\/li\u003e\n\u003cli\u003eelectrical power consumption 4.5 W\u003c\/li\u003e\n\u003cli\u003epower consumption standby 3.9 W\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kemper","offers":[{"title":"1","offer_id":56544024985986,"sku":"WCW-0214534-001","price":1353.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0928\/3675\/7890\/files\/4_c_e_f_4cef0304687d68aaa787193d257c510031427b6b_wcw_0214534_gl_image1_converted_500x500_kpb_68903007w_jpg.jpg?v=1775809081","url":"https:\/\/shop.we-connect.work\/en\/products\/kemper-khs-hygienespulung-pro-68903-1-anschluss-g-3-4","provider":"weconnectwork","version":"1.0","type":"link"}